Overview
Gayatri Aircon supplies, installs and maintains air-cooled screw and scroll chillers for industrial process cooling, commercial complexes, healthcare facilities and institutional campuses across Uttar Pradesh, Delhi NCR and Uttarakhand.
Air-cooled chillers reject heat directly to the atmosphere through fin-and-tube or microchannel condenser coils using heavy-duty axial fans. Unlike water-cooled chiller plants, air-cooled chillers eliminate the need for cooling towers, condenser water pumps, and continuous makeup water piping. They suit rooftop installations, sites with limited water and buildings with little plant room space.
We supply and commission air-cooled chillers from Daikin and Voltas. Depending on the model, they use R-134a, R-410A, R-32 or R-1234ze refrigerant, electronic expansion valves, VFD capacity control and multiple compressors for better part-load efficiency and standby capacity.
Where it is used
Pharmaceutical plants, Chemical processing, Hospitals & healthcare centers, Corporate office buildings, Shopping malls, Data centers, Plastic moulding and machine tool cooling
What our scope includes
- No cooling tower, so no make-up water, water treatment or tower-related Legionella risk
- Factory-packaged unit for rooftop or ground mounting, needing only piping and power connections
- VFD capacity control for better efficiency at part load
- Low-noise fans and compressor enclosures available for hospital and office sites
- Two independent refrigerant circuits, so one can run while the other is serviced
Typical technical data
| Capacity Range | 10 TR to 600+ TR per unit |
|---|---|
| Compressor Types | Semi-Hermetic Twin Screw, Inverter Scroll, Magnetic Centrifugal |
| Refrigerants | R-134a, R-410A, R-32, R-1234ze |
| Condenser Design | V-bank Microchannel / Copper tube aluminum fins |
| Operating Ambient | -5°C to +52°C peak ambient temperatures |
| BMS Controls | Microprocessor PLC with native BACnet / Modbus protocol |
| Evaporator | Direct Expansion Shell-and-Tube / Brazed Plate BPHE |
Figures are typical ranges for equipment we supply. Final selection depends on the heat load calculation and the manufacturer's data for the chosen model.
How we execute it
Survey and heat load
Site measurements and a room-wise load calculation.
Selection and BOQ
Equipment choice, layouts and itemised bill of quantities.
Installation
Equipment, piping, ducting, drains, electrical and controls.
Testing
Pressure test, vacuum, air balancing and performance readings.
Handover
Commissioning report, as-built drawings and operator training.
Maintenance
AMC with scheduled visits and breakdown support.
Frequently asked questions
What is the key advantage of an air-cooled chiller over a water-cooled chiller?
Air-cooled chillers reject heat directly into ambient air using fans, so they do not require a cooling tower, condenser water pumps, water piping, or chemical water treatment. This saves water, reduces mechanical room footprint, and simplifies maintenance.
Can air-cooled chillers operate during peak North Indian summer heat?
Yes, if the chiller is selected for high ambient conditions. We choose condenser coils and fans for North Indian summer temperatures and check the capacity the manufacturer states at that outdoor temperature.
Which brands of air-cooled chillers does Gayatri Aircon supply and install?
We install and service Daikin and Voltas air-cooled screw and scroll chillers, with manufacturer warranty and original spares.
What maintenance does an air-cooled chiller require?
Routine maintenance includes condenser coil cleaning, fin comb alignment, fan motor inspection, compressor oil analysis, refrigerant pressure checks, and control calibration, all covered under our comprehensive AMC plans.