ISO 9001:2015 certified HVAC service provider Mon to Sat, 9:30 am to 6:30 pm
Commercial & VRV Systems

Domestic Air Conditioning

Inverter split ACs, multi-split systems and window ACs for homes, villas and apartments, from Daikin and Voltas.

Domestic Air Conditioning

Overview

Gayatri Aircon Private Limited is an authorised channel partner and installation service provider for domestic air conditioning systems, with a Daikin Solution Plaza showroom in Haldwani and offices in Ghaziabad, Delhi and Gurugram. We supply, install and maintain inverter split ACs, multi-split systems, cassette units and window ACs from Daikin and Voltas.

Choosing the right domestic air conditioning system

For a home, the choice depends on room size, noise level, power consumption and how the unit fits the interiors:

  • 1-Way & 4-Way Inverter Split ACs: The usual choice for bedrooms and living rooms. Inverter compressors continuously modulate motor speed rather than switching on and off, which lowers power consumption compared with fixed-speed units and keeps the room temperature steady.
  • Multi-split systems for homes and villas: A single compact outdoor condensing unit connected to 2, 3, 4 or 5 indoor split or concealed units with independent room-by-room temperature controls. This avoids mounting several outdoor units on the facade or balcony.
  • Ceiling Concealed & Ductable Units for Penthouses: Slim ductable indoor units installed within false ceilings with linear grilles, used for drawing rooms and master bedrooms.

Tonnage sizing and load calculation

Selecting the correct AC tonnage prevents premature compressor wear and high power bills. We work out the load for each room based on:

  1. Floor area and ceiling height: A standard 120 sq. ft. room typically requires a 1.0 TR unit, while a 180 sq. ft. room requires 1.5 TR.
  2. Sun exposure and top-floor heat transfer: Top-floor rooms directly under concrete roof slabs or large south/west facing glass windows experience heavy solar heat gain and require 0.5 TR additional capacity or reflective roof insulation.
  3. Electrical safety and voltage stabilization: Modern inverter air conditioners from Daikin and Voltas operate smoothly between 130V and 285V with built-in electronic stabilizers.

Turnkey domestic installation & genuine copper piping

Most gas leaks and drainage problems in split ACs come from poor installation. Our standard practice:

  • Inner-grooved copper refrigerant piping: We never use cheap aluminum or alloy pipes. All installations use heavy-gauge copper coils with closed-cell elastomeric nitrile insulation to prevent sweat condensation inside walls.
  • Nitrogen Pressure & Electronic Vacuum Dehydration: Every refrigerant circuit is vacuum-pumped to below 500 microns to remove moisture and non-condensable atmospheric air before opening the refrigerant valves.
  • Anti-Vibration Wall & Terrace Mounting: Heavy-gauge powder-coated cantilever wall brackets with heavy rubber anti-vibration cushions keep vibration from reaching the bedroom walls.

Residential AMC & preventive maintenance

Gayatri Aircon offers comprehensive and non-comprehensive Annual Maintenance Contracts (AMC) for domestic split and window air conditioners. Scheduled pre-summer chemical wet jet servicing, coil cleaning, drainage descaling, and gas pressure checks keep the unit cooling properly through the summer.

Where it is used

Bedrooms, Living Rooms, Villas, Farmhouses, Penthouse Apartments, Home Offices, High-Rise Residential Societies

What our scope includes

  • Low indoor noise on night mode (from about 19 dB(A) on selected Daikin models)
  • Motion sensor on selected models that switches to energy-saving mode when the room is empty
  • PM 2.5 and titanium apatite deodorizing air purification filter capturing fine airborne particulates
  • Coanda airflow technology circulates cool air along the ceiling for uniform room cooling without direct cold drafts
  • Dual drainage outlets and anti-fungal self-cleaning evaporator coil prevents foul odors

Typical technical data

Tonnage Range0.8 TR, 1.0 TR, 1.5 TR, 1.8 TR, 2.0 TR, 2.5 TR
Energy RatingsBEE 3-Star & 5-Star Super-Inverter (High ISEER up to 5.4)
Compressor TechnologyDaikin Neo Swing Inverter / Voltas Dual Inverter Compressor
RefrigerantR-32 / R-410A (zero ozone depletion potential)
Heat ExchangerInner-grooved copper tube with Anti-Corrosion Hydrophilic Coating
Operating VoltageStabilizer-Free Operation (130V to 285V)
Warranty1 Year Comprehensive + 5 Years PCB + 10 Years Compressor Warranty

Figures are typical ranges for equipment we supply. Final selection depends on the heat load calculation and the manufacturer's data for the chosen model.

How we execute it

  1. Survey and heat load

    Site measurements and a room-wise load calculation.

  2. Selection and BOQ

    Equipment choice, layouts and itemised bill of quantities.

  3. Installation

    Equipment, piping, ducting, drains, electrical and controls.

  4. Testing

    Pressure test, vacuum, air balancing and performance readings.

  5. Handover

    Commissioning report, as-built drawings and operator training.

  6. Maintenance

    AMC with scheduled visits and breakdown support.

Frequently asked questions

How much power does an inverter split AC save compared to a non-inverter AC?

An inverter split AC usually uses less electricity than a fixed-speed unit, especially when it runs for long hours. Instead of constantly turning the compressor on and off at full power, an inverter modulates the compressor speed smoothly to match the exact cooling requirement of the room.

How do I choose between 1.0 Ton, 1.5 Ton and 2.0 Ton AC for my home?

For room areas up to 120-130 square feet, a 1.0 TR unit is suitable. For medium bedrooms and living rooms of 140 to 190 square feet, a 1.5 TR unit is standard. For rooms larger than 200 square feet, living-dining rooms, or top-floor rooms facing direct afternoon sun, a 2.0 TR unit is recommended.

Do Daikin and Voltas inverter ACs require an external voltage stabilizer?

Modern Daikin and Voltas inverter split air conditioners feature wide voltage stabilizer-free operation ranging from 130V to 285V. An external voltage stabilizer is only required in rural areas or colonies experiencing severe extreme voltage drops below 130V or surges above 290V.

Why do you use copper piping for split AC installation?

Copper conducts heat better, is stronger and resists corrosion better than aluminium. Copper flare joints hold the working pressure of R-32 refrigerant and are less likely to leak over the years.

Does Gayatri Aircon provide warranty and service for residential ACs?

Yes. Everything we supply carries the manufacturer's warranty, and our technicians handle servicing, breakdown calls and annual maintenance contracts for homes.

Planning a new HVAC installation or an AMC?

Share the building type, area and drawings if you have them. An engineer will call back to fix a site survey, usually within one working day.

Call +91 79833 80323 WhatsApp chat